321 research outputs found

    Image guidance in neurosurgical procedures, the "Visages" point of view.

    Get PDF
    This paper gives an overview of the evolution of clinical neuroinformatics in the domain of neurosurgery. It shows how image guided neurosurgery (IGNS) is evolving according to the integration of new imaging modalities before, during and after the surgical procedure and how this acts as the premise of the Operative Room of the future. These different issues, as addressed by the VisAGeS INRIA/INSERM U746 research team (http://www.irisa.fr/visages), are presented and discussed in order to exhibit the benefits of an integrated work between physicians (radiologists, neurologists and neurosurgeons) and computer scientists to give adequate answers toward a more effective use of images in IGNS

    Multimodal Hippocampal Subfield Grading For Alzheimer’s Disease Classification

    Get PDF
    Numerous studies have proposed biomarkers based on magnetic resonance imaging (MRI) to detect and predict the risk of evolution toward Alzheimer’s disease (AD). Most of these methods have focused on the hippocampus, which is known to be one of the earliest structures impacted by the disease. To date, patch-based grading approaches provide among the best biomarkers based on the hippocampus. However, this structure is complex and is divided into different subfields, not equally impacted by AD. Former in-vivo imaging studies mainly investigated structural alterations of these subfields using volumetric measurements and microstructural modifications with mean diffusivity measurements. The aim of our work is to improve the current classification performances based on the hippocampus with a new multimodal patch-based framework combining structural and diffusivity MRI. The combination of these two MRI modalities enables the capture of subtle structural and microstructural alterations. Moreover, we propose to study the efficiency of this new framework applied to the hippocampal subfields. To this end, we compare the classification accuracy provided by the different hippocampal subfields using volume, mean diffusivity, and our novel multimodal patch-based grading framework combining structural and diffusion MRI. The experiments conducted in this work show that our new multimodal patch-based method applied to the whole hippocampus provides the most discriminating biomarker for advanced AD detection while our new framework applied into subiculum obtains the best results for AD prediction, improving by two percentage points the accuracy compared to the whole hippocampus

    SoLid : Search for Oscillations with Lithium-6 Detector at the SCK-CEN BR2 reactor

    Get PDF
    Sterile neutrinos have been considered as a possible explanation for the recent reactor and Gallium anomalies arising from reanalysis of reactor flux and calibration data of previous neutrino experiments. A way to test this hypothesis is to look for distortions of the anti-neutrino energy caused by oscillation from active to sterile neutrino at close stand-off (similar to 6-8m) of a compact reactor core. Due to the low rate of anti-neutrino interactions the main challenge in such measurement is to control the high level of gamma rays and neutron background. The SoLid experiment is a proposal to search for active-to-sterile anti-neutrino oscillation at very short baseline of the SCK center dot CEN BR2 research reactor. This experiment uses a novel approach to detect anti-neutrino with a highly segmented detector based on Lithium-6. With the combination of high granularity, high neutron-gamma discrimination using 6LiF:ZnS(Ag) and precise localization of the Inverse Beta Decay products, a better experimental sensitivity can be achieved compared to other state-of-the-art technology. This compact system requires minimum passive shielding allowing for very close stand off to the reactor. The experimental set up of the SoLid experiment and the BR2 reactor will be presented. The new principle of neutrino detection and the detector design with expected performance will be described. The expected sensitivity to new oscillations of the SoLid detector as well as the first measurements made with the 8 kg prototype detector deployed at the BR2 reactor in 2013-2014 will be reported

    Evolution of the X-ray spectrum in the flare model of Active Galactic Nuclei

    Full text link
    Nayakshin & Kazanas (2002) have considered the time-dependent illumination of an accretion disc in Active Galactic Nuclei, in the lamppost model. We extend their study to the flare model, which postulates the release of a large X-ray flux above a small region of the accretion disc. A fundamental difference with the lamppost model is that the region of the disc below the flare is not illuminated before the onset of the flare. A few test models show that the spectrum which follows immediately the increase in continuum flux should display the characteristics of a highly illuminated but dense gas, i.e. very intense X-ray emission lines and ionization edges in the soft X-ray range. The behaviour of the iron line is different in the case of a "moderate" and a ``strong'' flare: for a moderate flare, the spectrum displays a neutral component of the Fe Kα\alpha line at 6.4 keV, gradually leading to more highly ionized lines. For a strong flare, the lines are already emitted by FeXXV (around 6.7 keV) after the onset, and have an equivalent width of several hundreds of eV. We find that the observed correlations between RR, Γ\Gamma, and the X-ray flux, are well accounted by a combination of flares having not achieved pressure equilibrium, strongly suggesting that the observed spectrum is dominated by regions in non-pressure equilibrium, typical of the onset of the flares. Finally a flare being confined to a small region of the disc, the spectral lines should be narrow (except for a weak Compton broadening), Doppler shifted, and moving.Comment: 14 pages, 13 figures, accepted in A & A, english corrected versio

    Mixed-Model Noise Removal in 3D MRI via Rotation-and-Scale Invariant Non-Local Means

    Get PDF
    Mixed noise is a major issue influencing quantitative analysis in different forms of magnetic resonance image (MRI), such as T1 and diffusion image like DWI and DTI. Using different filters sequentially to remove mixed noise will severely deteriorate such medical images. We present a novel algorithm called rotation-and-scale invariant nonlocal means filter (RSNLM) to simultaneously remove mixed noise from different kinds of three-dimensional (3D) MRI images. First, we design a new similarity weights, including rank-ordered absolute difference (ROAD), coming from a trilateral filter (TriF) that is obtained to detect the mixed and high-level noise. Then, we present a shape view to consider the MRI data as a 3D operator, with which the similarity between the patches is calculated with the rigid transformation. The translation, rotation and scale have no influence on the similarity. Finally, the adaptive parameter estimation method of ROAD is illustrated, and the effective proof that validates the proposed algorithm is presented. Experiments using synthetic data with impulse noise, Rician noise, and the real MRI data confirm that the proposed method yields superior performance compared with current state-of-the-art methods

    Evaluation of the benefits, harms and cost‐effectiveness of potential alternatives to iFOBT testing for colorectal cancer screening in Australia

    Get PDF
    The Australian National Bowel Cancer Screening Program (NBCSP) will fully roll‐out 2‐yearly screening using the immunochemical Faecal Occult Blood Testing (iFOBT) in people aged 50 to 74 years by 2020. In this study, we aimed to estimate the comparative health benefits, harms, and cost‐effectiveness of screening with iFOBT, versus other potential alternative or adjunctive technologies. A comprehensive validated microsimulation model, Policy1‐Bowel, was used to simulate a total of 13 screening approaches involving use of iFOBT, colonoscopy, sigmoidoscopy, computed tomographic colonography (CTC), faecal DNA (fDNA) and plasma DNA (pDNA), in people aged 50 to 74 years. All strategies were evaluated in three scenarios: (i) perfect adherence, (ii) high (but imperfect) adherence, and (iii) low adherence. When assuming perfect adherence, the most effective strategies involved using iFOBT (annually, or biennially with/without adjunct sigmoidoscopy either at 50, or at 54, 64 and 74 years for individuals with negative iFOBT), or colonoscopy (10‐yearly, or once‐off at 50 years combined with biennial iFOBT). Colorectal cancer incidence (mortality) reductions for these strategies were 51–67(74–80)% in comparison with no screening; 2‐yearly iFOBT screening (i.e. the NBCSP) would be associated with reductions of 51(74)%. Only 2‐yearly iFOBT screening was found to be cost‐effective in all scenarios in context of an indicative willingness‐to‐pay threshold of A50,000/life‐yearsaved(LYS);thisstrategywasassociatedwithanincrementalcost‐effectivenessratioofA50,000/life‐year saved (LYS); this strategy was associated with an incremental cost‐effectiveness ratio of A2,984/LYS–A$5,981/LYS (depending on adherence). The fully rolled‐out NBCSP is highly cost‐effective, and is also one of the most effective approaches for bowel cancer screening in Australia

    Towards a comprehensive evaluation of ultrasound speckle reduction

    Get PDF
    Over the last three decades, several despeckling filters have been developed to reduce the speckle noise inherently present in ultrasound images without losing the diagnostic information. In this paper, a new intensity and feature preservation evaluation metric for full speckle reduction evaluation is proposed based contrast and feature similarities. A comparison of the despeckling methods is done, using quality metrics and visual interpretation of images profiles to evaluate their performance and show the benefits each one can contribute to noise reduction and feature preservation. To test the methods, noise-free images and simulated B-mode ultrasound images are used. This way, the despeckling techniques can be compared using numeric metrics, taking the noise-free image as a reference. In this study, a total of seventeen different speckle reduction algorithms have been documented based on adaptive filtering, diffusion filtering and wavelet filtering, with sixteen qualitative metrics estimation.info:eu-repo/semantics/publishedVersio
    • 

    corecore